Q26 IN SITU SYNTHETIC SURFACING

Q26 Special surfacing/ pavings for sports/ general amenityIMPACT ABSORBING SURFACINGS FOR PLAY AREAS300 EXTENT OF IMPACT ABSORBING SURFACING
  • · General: Lay to the impact areas shown in the relevant parts of BS EN 1176.
301 EXTENT OF IMPACT ABSORBING SURFACING
  • · General: Lay impact absorbing surfacing as indicated on drawings.
360 IN SITU SYNTHETIC SURFACING
  • · Sub-base: Base Course Macadam
– Thickness: 125mm Type 1 MOT– Thickness: 50mm Open Textured 20mm aggregate base course macadam– Manufacturer: Sports & Safety Surfaces, Tel: 01625 445766
  • · Base: 2-6mm SBR rubber granule material
– Thickness: To suit the test certificate BS EN 1177
  • · Surface Course: Wet-Pour, in situ laid polyurethane bound EPDM rubber crumb surface.
– Standard: To BS 7188– Manufacturer: Soft Surfaces Ltd, 35 Water Lane, Wilmslow, SK9 5AR– Tel: 01625 445760, Fax: 01625 525619– Email: info@softsurfaces.co.uk Website: www.softsurfaces.co.uk– Colour: From standard colour range– Features: From wide range of graphics available, Tel: 01625 445767– Critical Fall Height when tested to BS EN 1177: TBC– Health and Safety: CHAS accredited, API accredited, CONSTRUCTIONLINE accreditedSubstance known to be toxic or carcinogenic on skin or released as vapour or dust during normal use: Not permitted.
  • · Submit:
– Resistance to abrasive wear, slip resistance, resistance to indentation and ease of ignition: Evidence of testing to BS 7188.– Critical Fall Height: Evidence of testing to BS EN 1177.COMPLETION920 PLAY SURFACE TESTING
  • · Standard: To BS EN 1177 and BS 1177, where applicable.
  • · Testing Body: A United Kingdom Accreditation Service (UKAS) independent laboratory.
  • · Timing: Within ten days of completing the surface works.
  • · Test Results: Submit.
930 DOCUMENTATION
  • · General: For all types of surfacing, provide the following:
– Name and contact details of installer.– Date of installation.– Name and contact details of manufacturer.– Type/ description/ reference of products used.– Manufacturer’s recommended inspection and maintenance procedures to maintain safety and impact absorbing performance.– Manufacturer’s recommended cleaning and maintenance methods, where relevant.940 LABELLING
  • · Signs: Provide permanent labelling in approved locations on all types of surfacing stating:
– Critical Fall Height;– Date of Installation– Manufacturer’s name and contact details; and– Product name